
The vibration motor is an excitation source that combines the power source and the vibration source. A set of adjustable eccentric blocks are installed at each end of the rotor shaft, and the excitation force is obtained by the centrifugal force generated by the high-speed rotation of the shaft and the eccentric block.
1. The stator winding is short-circuited between phases, the stator winding is open-circuited, and grounded
2. Wrong connection of stator winding
3. The load is too heavy or the rotor is blocked
Solution
1. Check the open circuit, short-circuit grounding part, and repair it
2. Check the winding wiring and correct it
3. Lighten the load and remove obstacles
1. Overload
2. Winding short circuit
3. Wrong winding connection
4. Winding grounding or short circuit between turns
5. The rotor of the vibration motor is broken
6. The stator and rotor are rubbed
Solution
1. Reduce the load or replace the vibration motor.
2. Repair the short-circuit part.
3. Check the winding wiring and correct it.
4. Find the fault and repair it.
5. Replace the rotor to repair.
1. Bearing wear or quality problems
2. Too much or too little bearing grease, wrong type or bad quality
3. The fit between the inner ring of the bearing and the shaft is too loose or too tight
4. The fit between the bearing outer ring and the end cover is too loose or too tight
5. The assembly quality of the end cover and the bearing inner cover is not good
Solution
1. Replace the bearing
2. Adjust the grease
3. When it is too loose, a circle of metal can be welded on the shaft for reprocessing. When it is too tight, the bearing gear can be reprocessed.
4. When it is too loose, the bearing chamber of the end cover can be enlarged and then inserted into the sleeve. When it is too tight, the bearing can be reprocessed. Chamber
5. Remove and re-install, so that the bearing force is even
1. Poor grounding
2. Damaged winding insulation
3. The winding is damp
4. The wiring board is damaged, or there is too much dust
Solution
1. Find the cause and fix it
2. Repair insulation and do dipping and drying treatment
3. Drying treatment or dipping paint drying
4. Replace the wiring board and clean up the dirt
1. The anchor bolts are not tightened
2. The installation plane is not flat enough
Solution
1. Regularly tighten the bolts
2. Rework the installation plane